Common Issues Of Tiantai Beer Fermenters During Using
Conical fermenters already extensively utilized, but as a result of bigger fermenters design and manufacture, procedure piping arrangement, instrument making use of, various other equipment and accessory enhancement etc might exist some concerns, which may cause occur unusual check in the process of creating. It includes:
1. Leakage on bigger capacity tanks Leak is common indicator on fermenter storage tank, primarily take place at storage tanks top. If the seal is not well or valves seal is not well during feeding, fermenting, filtering system procedure, both can result in containers leakage. After leak, containers stress can not keep and CO2 quantity come to be reduced.
2. Beer cold To avoid the beer cold on storage tanks covering, glycol temperature is not ideal over reduced. The glycol inlet also must not create at reduced temperature level location of tanks, or it also simple to make beer cold.
3. Slope circulation The height of tanks greater than 10 meters, convection is not well, as well as temperature differential between top and also bottom liquid, various liquid density, additional CO2 quantity is greater on bottom( reduced on top), so it might exist slope circulation indication, which brings troubles for beer quality.
4. It can be addressed by follows: 1) Install CO2 cleansing gadget on containers leading, promoting beer blended well throughout washing fermenting fluid.
2) Design two sample port on top and bottom, taking example and blending make sample representative.
3) Using glycol jacket on fermentation storage tanks sensibly.
5. Storage tanks Contamination 1) Large containers surface, as an example tidy not well result in contamination.
2) More piping connection, cleansing as well as sanitation require to be noticed.
3) During manufacturing process, product or air in and also out multi times, if it have microorganisms will certainly cause contamination.
6. Tool error Due to top quality issues or incorrect operation, it may make instrument not wort well. It mainly showed on temperature, level, stress, clean impact. The way to fix is embrace high quality tool and also regular maintenance and also evaluating.
7. Improperly CIP cleaning 2 factors: One is not ideal installations, an additional one is unreasonable clean agent.
Leak is typical indicator on fermenter storage tank, mainly take place at storage tanks leading. If the seal is not well or valves seal is not well during feeding, fermenting, filtering system procedure, both can result in tanks leakage. After leak, storage tanks pressure can not keep as well as CO2 quantity become lower. To stay clear of the beer freezing on containers covering, glycol temperature level is not suitable over lower. The glycol inlet additionally ought to not create at lower temperature location of tanks, or it also very easy to make beer freezing.
Request A Quote